One stop shop and
accessories required for a solar plant

Weather Sensors Lufft

Lufft

Lufft

 

WS600-UMB
Compact Weather Station

WS600 UMB compact weather station

•Air temperature,
•Relative humidity,
•Precipitation intensity,
•Precipitation type,
•Precipitation quantity,
•Air pressure,
•Wind direction,
•Wind speed,
All in one
Aspirated temperature/ humidity measurement
Maintenance-free operation
Open communication protocol:
– ASCII
– UMB
– SDI12
– MODBUS
– Analoge outputs in combination with 8160.UDAC

General Information
Heating 40 VA at 24 VDC
Protection type housing IP66
Interface RS485, 2-wire, half-duplex
Op. power consumption 24 VDC ±10 % < 0.4 VA(without heating)
Operating humidity range 0 … 100 %
Op. temperature range –50 … 60 ° C
Technical Data
Dimensions Ø approx. 150 mm, height approx. 345 mm
Weight approx. 2.2 kg
Temperature
Principle NTC
Measuring range –50 … 60 ° C
Accuracy ±0.2 ° C (–20 ° C … +50 ° C),otherwise ±0.5 ° C ( > –30 ° C)
Relative humidity
Principle Capacitive
Measuring range 0 … 100 % RH
Accuracy ±2 % RH
Precipitation intensity
Resolution 0.01 mm
Measuring range Drop size 0.3 … 5 mm
Reproducibility typ. > 90 %
Precipitation type
Rain/snow
Air pressure
Principle MEMS capacitive
Measuring range 300 … 1200 hPa
Accuracy ±1.5 hPa
Wind direction
Principle Ultrasonic
Measuring range 0 … 359.9 °
Accuracy ±3 °
Wind speed
Principle Ultrasonic
Measuring range 0 … 60 m/s
Accuracy ± 0.3 m/s or ±3 % (0 … 35 m/s)
Accessories
Surge protection
Power supply 24V/4A
UMB Interface converter ISOCON
Digital-analog-converter

 


WS501-UMB
Compact Weather Station

WS501 UMB compact weather station

•Air Temperature,
•Relative Humidity,
•Air Pressure,
•Wind direction,
•Wind speed,
•Solar Radiation
All in one
Aspirated temperature/ humidity measurement
Maintenance-free operation
Open communication protocol:
– ASCII
– UMB
– SDI12
– MODBUS
– Analoge outputs in combination with 8160.UDAC

General Information
Heating 20 VA at 24 VDC
Protection type housing IP66
Interface RS485, 2-wire, half-duplex
Operating power consumption 24 VDC±10 % <0. 4 VA(without heating)
Operating humidity range 0 … 100 %
Operating temperature range –50 … 60 ° C
Accessories
Surge protection
Power supply 24V/4A
UMB Interface converter ISOCON
Digital-analog-converter
Technical Data
Dimensions Ø approx. 150 mm, height 345 mm
Weight approx. 2.2 kg
Temperature
Principle NTC
Measuring range –50 … 60 ° C
Accuracy ±0.2 ° C (–20 ° C … +50 ° C),otherwise ±0.5 ° C ( =30 ° C)
Relative humidity
Principle Capacitive
Measuring range 0 … 100 % RH
Accuracy ±2 % RH
Radiation
Response time(95%) 18s
Non-stability (change/year) ±1 %
Non-linearity (0 to 1,000 W/m2) ±2.5 %
Directional error(at 80 ° with 1,000 W/m2) ±20 W/m2
Temperature dependence ofsensitivity ±5 % (–10 to +40 ° C)
Tilt error (at 1000 W/m2) ±3 %
Spectral range (50% points) 300 to 2,800 nm
Maximum irradiance 1,500 W/m2
Air pressure
Principle MEMS capacitive
Measuring range 300 … 1200 hPa
Accuracy ±1.5 hPa
Wind direction
Principle Ultrasonic
Measuring range 0 … 359.9 °
Accuracy ±3 °
Wind speed
Principle Ultrasonic
Measuring range 0 … 60 m/s
Accuracy ± 0.3 m/s or ±3 % (0 … 35 m/s)

 

WS601 UMB weather station WS600 UMB weather station WS501 UMB weather station WS301 UMB weather station
UMB-Sensor Overview WS601-UMB WS600-UMB WS501-UMB WS301-UMB
Temperature
Rel. humidity
Precipitation type
Precipitation intensity)
Rain accumulation
Leaf wetness
Air pressure
Wind direction
Wind speed
Electronic Compass
Radiance (solar radiation)
Visibility
Snow hight

 

WS500 UMB weather station WS401 UMB weather station ventus UMB weather station R2S UMB weather station
UMB-Sensor Overview WS500-UMB WS401-UMB VENTUS-UMB R2S-UMB
Temperature
Rel. humidity
Precipitation type
Precipitation intensity)
Rain accumulation
Leaf wetness
Air pressure
Wind direction
Wind speed
Electronic Compass
Radiance (solar radiation)
Visibility
Snow hight