Energie

NOTES ON SAFETY, INSTALLATION & OPERATION DC EV charging connector with cable

Combined Charging System Type 2- Charging Connector with open end Cable, Suitable for charging in MODE 4

S 17017 (Part 2 / Sec 3)- IV C

IEC 62196-3

011710075 – TTEV-80ADC-CCS…….

011710076 – TTEV-150ADC-CCS……

011710077 – TTEV-200ADC-CCS……

Picture – 1

Picture – 2

Picture – 3

Connection Color 80A 150A 200A
DC+ RD 16 mm² 50 mm² 70 mm²
DC- BK 16 mm² 50 mm² 70 mm²
PE GNYE 16 mm² 25 mm² 35 mm²
CP BN 0.75 mm²
PP GY 0.75 mm²
Temperature sensor 1 DC+ BU + OG 0.75 mm² + 0.75 mm²
Temperature sensor 2 DC- WH + VT 0.75 mm² + 0.75 mm²
Resistance Between PE & PP) 1500 Ω
Type 80 A DC 150 A DC 200 A DC
Charging mode, Charging case Mode 4
Rated Current for power contact 80 A 150 A 200 A
Power Contact 3 ( DC+, DC-, PE)
Rated Voltage for Power contact 1000V DC
Signal contact 2 (CP & PP)
Rated Current for signal contact 2 A
Rated voltage for signal contact 30V AC
IEC Compliance IEC 62196-3, IEC 62196-1
Rated Power KW 80 kW 150 kW 200 kW
Cable Standard DIN EN 50620
Cable outer sheath TPE-U
Cable Structure (IEC50620) 3 x 16 mm² +
3 x 2 x 0.75 mm²
2 x 50 mm² + 1 x 25 mm² +
3 x 2 x 0.75 mm²
2 x 70 mm² + 1 x 35 mm² +
3 x 2 x 0.75 mm²
External Cable Diameter 20.5 mm 27.5 mm 34 mm
Resistance (between PE and PP) 1500Ω
Temperature Monitoring 2 X Pt 1000 (SENSORS FOR DC CONTACTS)
Temperature sensor Standard DIN EN 60751
Ambient Operating Temperature -30˚C to +50˚C
Insertion & Withdrawn Force Less than 100 N
Mating Cycle (No Load) ≥10000
Degree of Protection IP44 (Mated), IP20 (Un-mated)
Degree
Housing material Thermoplastic
Flammability UL94 V0
Power contact material Copper- with Ag coating